A-A-1864A
September 5, 1984
SUPERSEDING
A-A-1864
June 12, 1981
COMMERCIAL ITEM DESCRIPTION
LAMP, FLUORESCENT
(F96T12/CW/HO ENERGY SAVING)
The General Services Administration has authorized the use of this commercial item description in preference to Federal Specification W-L-00116D/GEN and W-L-00116/55.
This commercial item description covers 95/100 watt, rapid-start type, high output, energy saving fluorescent lamps at 800 ma operation.
Salient characteristics.
Bulb – T – 12
Nominal length – 96 inches
Base – Recessed double contact
Average rated life – 3 hours per start – 12,000 hours
Initial lumen (after 100 hours burning) – 8000 lumens
Lumens at 40 percent of life – 6700 lumens
Color – Cool white when tested in accordance with ANSI C78.376
Designed to operate on one – or two-lamp, lead-circuit, high power factor, rapid-start indoor ballasts that meet ANSI C82 and UL Standard 935 requirements, and in ambient temperature of not less than 18 degrees C (65 degrees F)
The issues of ANSI C78.1, ANSI C78.376, ANSI C82, and UL Standard 935 in effect on the date of the solicitation shall be used to determine compliance with these requirements.
Regulatory requirements. The offeror/contractor is encouraged to use recovered materials in accordance with Public Law 94-580, to the maximum extent practical.
Preservation, packaging, packing, labeling, and marking. Preservation, packaging, packing, labeling, and marking shall be as specified in the contract or order.
Preproduction inspection. One package of lamps, produced using the same tooling, production, and assembly method that are used for production lots, shall be submitted for examination and test in accordance with the above requirements. Documentation consisting of the certification and test data shall be presented for examination during performance of the preproduction inspection. Failure of the preproduction samples to pass the examination of one or more of the tests, the lack of required documentation, or failure of the documentation to substantiate conformance to the requirements of this CID shall be cause for rejection.
Notes. Copies of ANSI Standards are available from the American National Standards Institute, 1430 Broadway, New York, NY 10018.
UL Standard No. 935 is available from Underwriter’s Laboratories, Inc., 333 Pfingsten Road, Northbrook, IL 60062.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business