A-A-2223
July 25, 1984
COMMERCIAL ITEM DESCRIPTION
LAMP, MERCURY VAPOR (TRADE NO. H33 GL – 400/C)
The General Services Administration has authorized the use of this commercial item description.
This description covers a color-improved mercury vapor lamp.
Salient characteristics.
Bulb – BT-37 or E37.
Watts – 400
Base – Mogul screw base, brass.
Maximum overall length – 11-5/16 inches.
Rated life – 24,000 hours.
Burning postion – any
Approximate lumens – vertical operation.
Initial – 20,500*
Mean – 18,570**
To be used on Mercury lamp ballasts H1 or H33, ANSI Standards C82.7 and C82.5.
* Initial lumen ratings are based on photometry of lamps operating vertically,on a standard reference ballast, after lamps have been operated for 100 hours.
** Mean lumen ratings based on photometry of lamps operating vertically,on a standard reference ballast, after lamps have been operated 50 percent of their rated life at 10 hours per start on typical commercial ballast.
The lamp shall be measured in accordance with ANSI Standard C78.386.
The issue of the above ANSI Standard in effect on the date of solicitation shall be used to determine compliance with these requirements.
Regulatory requirements. The offeror/contractor is encouraged to use recovered materials in accordance with Public Law 94-580 to the maximum extent practical.
Preservation, packaging, packing, labeling, and marking. The preservation, packaging, packing, labeling and marking shall be as specified in the contract or order.
Preproduction inspection. One package of lamps, produced using the same tooling, production, and assembly methods that are used for production lots, shall be submitted for examination and test in accordance with the above requirements. Documentation consisting of the certification and test data shall be presented for examination during performance of the preproduction inspection. Failure of the preproduction samples to pass the examination of one or more of the tests, the lack of required documentation, or failue of the documentation to substantiate conformance to the requirements of this CID shall be cause for rejection.