MIL-DTL-6363/4A
7.
Solderability: Applicable.
High temperature: Applicable for qualification tests only (85°C/185F°).
8.
9.
Thermal shock: Applicable for qualification tests only. Use temperatures for Type I
lamps.
10.
Random vibration: Applicable for qualification tests only - See figure 2 for random
vibration curves. For vibration tests, the lamps shall be potted in a clear epoxy block
which shall be rigidly mounted to the vibration table.
11.
Shock: Applicable for qualification tests only - See table I for applicable "g" level. For
shock tests, the lamps shall be potted in a clear epoxy block which shall be rigidly
mounted to the shock machine.
12.
Humidity: Applicable for qualification tests only.
13.
Salt spray: Applicable for qualification tests only.
14.
Marking: Lamps do not require marking. Unit packages and containers shall be marked
as specified in section 5 of MIL-DTL-6363.
Production lamps qualified to MIL-DTL-6363 and listed on QPL-6363 shall be identified on
packages and containers in accordance with ANSI-C78.390 and as supplemented herein. ANSI-
C78.390 authorized suffix letters shall be supplemented with the letter "Q" (MIL-DTL-6363
QPL item). The letter "Q" shall be incorporated into the method of designation in accordance
with the following example:
EXAMPLE
XXX
XXXX
Q
AS15
|
|
|
|
Manufacturers__|
|
|
|___Added after aging
Identification
|
|
and selection for
|
|
15 percent tolerance
Industry____________________|
|
on MSCD
(ANSI)
|
Lamp number
|___Qualified to MIL-DTL-6363
15.
Interchangeability: These lamps may be similar to, but are not interchangeable with,
other commercial or military lamps due to unique aircraft applications and qualification.