MIL-DTL-6363/13A
6.
Thermal shock: Applicable for qualification tests only. Use temperatures for Type I
lamps..
7.
Random vibration: Applicable for qualification tests only. See figure 2 for random
vibration curve.
8.
Shock: Applicable for qualification tests only. See table I for applicable "g" level.
9.
Humidity: Applicable for qualification tests only.
10.
Salt spray: Applicable for qualification tests only.
11.
Marking: Production lamps qualified to MIL-DTL-6363 and listed on QPL-6363 shall be
marked in accordance with ANSI-C78.390 and as supplemented herein. ANSI-C78.390
authorized suffix letters shall be supplemented with the letter "Q" (MIL-DTL-6363 QPL
item). The letter "Q" shall be incorporated into the method of designation in accordance
with the following example:
EXAMPLE
XXX
XXX
Q
|
|
|
Manufacturers__|
|
|___Qualified to MIL-DTL-6363
Identification
|
|
Industry____________________|
(ANSI) Lamp part number
12.
Interchangeability: These lamps may be similar to, but are not interchangeable with, other
commercial or military lamps due to unique aircraft applications and qualification.
There are no technical changes in this revision.