MIL-DTL-6363/3D
NOTES:
1.
Dimensions are in inches. Unless otherwise specified, tolerances:
decimals ±0.010 inch, angles ±0.5°.
2.
Intended use - aircraft navigational light assemblies.
3.
For design feature purposes, this specification takes precedence over procurement
documents referenced herein.
REQUIREMENTS:
1.
Configuration and dimensions: See figure 1.
2.
Finish: Glass globe shall be clear except where reflector surface is required.
3.
Lamp operating characteristics: When operating at rated voltage (DC), the lamp operating
characteristics shall be as specified in table I.
TABLE I. Part numbers and operating characteristics.
Type
Temp Rating
Shock
Average
Military
Per
Continuous
Test
Electrical Ratings
Rated Lab
Part
MIL-DTL-
Operation 1/
Level
Volts Amperes Watts
Life at DC
°C
°F
Number
6363
(G's)
(Nom) (Max)
(Max)
Hours
M6363/3-1
II
113
235
90
28.0
1.55
43
300
M6363/3-2
II
113
235
135
6.2
6.93
43
300
1/
For 70 percent of average rated lab life.
4.
Light distribution: See tables II and III.
TABLE II. Light distribution (horizontal plane).
LIGHT DISTRIBUTION IN HORIZONTAL PLANE CONTAINING FLIGHT AXIS (0°)
AND PASSING THROUGH LIGHT CENTER AND CENTER OF INDEXING PINS
Beam Candlepower
Angle of Distribution
Candelas (Minimum)
0° forward to 30° outboard
300
30° outboard to 40° outboard
150
40° outboard to 50° outboard
120
50° outboard to 100° outboard
50
2