MIL-DTL-6363/3D
TABLE III. Light distribution (vertical plane).
LIGHT DISTRIBUTION IN VERTICAL PLANE CONTAINING FLIGHT AXIS (0°) AND
PASSING THROUGH LIGHT CENTER AND PERPENDICULAR TO HORIZONTAL
PLANE ABOVE
Beam Candlepower
Angle of Distribution
Candelas (Minimum)
0° to 20° above and below flight axis
300
20° to 40° above and below flight axis
60
40° to 85° above and below flight axis
30
5.
Coating adhesion: Applicable.
6.
High temperature: See table I for applicable high temperature rating.
7.
Thermal shock: See table I for applicable high temperature rating.
8.
Random vibration: See figure 2 for 28.0v lamp and figure 3 for 6.2v lamp random
vibration curves.
9.
Shock: See table I for applicable "g" level.
10.
Humidity: Applicable.
11.
Salt spray: Applicable
12.
Inspection lot vibration screening: Sample size and acceptance level as specified by the
procuring activity.
13.
Marking: Lamps shall be marked with the applicable military part number from table I,
voltage rating, manufacturing lot code, and the manufacturer's name, CAGE code,
abbreviation or trademark. Other military or commercial lamp numbers shall not be
marked on the lamps.
14.
Interchangeability: These lamps may be similar to, but are not interchangeable with, other
commercial or military lamps due to unique aircraft applications and qualification.
There are no technical changes in this revision.
3