MIL-DTL-15098E
DEPARTMENT OF DEFENSE SPECIFICATIONS
(See supplement 1 for list of specification sheets.)
DEPARTMENT OF DEFENSE STANDARDS
MIL-STD-202
- Test Method Standard Electronic and Electrical
Component Parts
MIL-STD-1285
- Marking of Electrical and Electronic Parts
(Copies of these documents are available online at https://assist.daps.dla.mil/ or from the
Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA
19111-5094.)
2.3 Non-government publications. The following document forms a part of this document
to the extent specified herein. Unless otherwise specified, the issues of these documents are those
cited in the solicitation or contract.
AMERICAN SOCIETY FOR QUALITY (ASQ)
ASQ Z1.4
- Sampling Procedures and Tables for Inspection by
Attributes
(Copies of this document are available online at https://www.asq.org/ or from American Society
of Quality, 600 North Plankinton Avenue, Milwaukee, WI 53203.)
2.4 Order of precedence. Unless otherwise noted herein or in the contract, in the event
of a conflict between the text of this document and the references cited herein (except for related
specification sheets), the text of this document takes precedence. Nothing in this document,
however, supersedes applicable laws and regulations unless a specific exemption has been
obtained.
3. REQUIREMENTS
3.1 Specification sheets. The individual item requirements shall be as specified herein
and in accordance with the applicable specification sheets. In the event of any conflict between
the requirements of this specification and the specification sheet, the latter shall govern.
3.2 First article. When specified (see 6.2), the contractor shall furnish sample units for
first article inspection and approval (see 4.3).
3.3 General characteristics. The general characteristics of glow lamps shall be such that
once a discharge has commenced, the voltage drop across the electrodes remains essentially
constant throughout an appreciable change in current flow. This entails the insertion of a current
limiting resistor (see 3.4), so calculated that current cannot exceed a predetermined value. No
post-delivery aging or conditioning shall be required to achieve the stability and reliability
needed to meet the applicable performance requirements stated herein.